Client: |
|
Address: |
|
Property Description: |
(2) story single family home |
Property age/ size: |
Built 2007, 2,874 s.f. per listing |
Occupancy Status: |
Occupied |
Inspection Date: |
02/07/2012 |
Inspection Time: |
12:45 P.M. – 3:15 P.M. |
Weather Conditions: |
Clear, 50 deg F +- |
Summary of Inspection....................................................................................................... 3
Electrical System................................................................................................................. 5
Plumbing System................................................................................................................. 7
Heating System................................................................................................................... 8
Water Heater..................................................................................................................... 11
Site..................................................................................................................................... 12
Building Exterior............................................................................................................... 13
Crawlspace........................................................................................................................ 16
Garage............................................................................................................................... 19
Living Room and Dining Room........................................................................................ 20
Kitchen.............................................................................................................................. 21
Family Room and Nook.................................................................................................... 23
Powder Room.................................................................................................................... 24
Guest Suite........................................................................................................................ 25
Hallways............................................................................................................................ 26
Master Bedroom Suite....................................................................................................... 27
Bedrooms 2 and 3............................................................................................................. 29
Main Bathroom.................................................................................................................. 30
Utility Room...................................................................................................................... 31
Attic................................................................................................................................... 32
Structural Pest Inspection Diagram................................................................................... 34
All items listed in the Summary of each section are listed below. Additional comments may be written in the body of the report. Please read the entire report. All items listed below should be further evaluated, inspected, modified, and/or corrected by a licensed professional in that corresponding or related trade.
WDO refers to “Wood Destroying Organism” as defined by the Washington State Department of Agriculture
- Items in this font are general comments throughout report.
- Items in this font are considered a minor cost and/or cosmetic.
- Items in this font are considered a substantial cost or an extreme safety concern.
Electrical System
Plumbing System
- Recommend consultation with licensed septic system installer regarding the proper operation and maintenance of this septic system
Heating System
- Recommend servicing of furnace by a licensed furnace technician and every (2) years thereafter. There is no visible tag that this furnace has ever been serviced
Water Heater
Site
- Structure in contact with ground (WDO conducive condition). Recommend 4-6” separation between ground and structure
Building Exterior
- South wall of house should be re-caulked and maintained. This wall is in direct exposure to the Sun
- Roofing or flashing should be installed at all fascia tails
- Minor improper slope at gutters above the Living room and Dining room. Minor debris, including roof granules, in these gutters
- New downspouts above the Living Room and Dining room and an extension above the garage by the entry may extend the useful life of these roofing areas
Crawlspace
- Air and heat loss at trunk line (approximately 10 feet from the crawl access)
Garage
- Base weather-stripping damaged at rear garage door
Living Room and Dining Room
Kitchen
- Garbage disposals are typically not recommended with a septic system. Recommend consultation with licensed septic system installer
- Faucet spray handle counterweight needs adjustment (to hold spray handle tight to faucet)
- Garden window spring is detached (left window)
Family Room and Nook
- Window screen at Nook window is torn
- Door latch at rear exterior door needs adjustment or replacement
Powder Room
- Recommend re-grout floor tiles adjacent to hardwood floor
Guest Suite
Hallways
Master Bedroom Suite
- Recommend re-caulk the base of the shower pan
Bedrooms 2 and 3
Main Bathroom
- Bathroom door does not latch
Utility Room
Attic
- Evidence of microbial growth above the Master Bathroom and North wall above the Master Bedroom. Recommend install timer style bathroom fan switch and additional roof ventilation above the North roof area
|
|
|
|
|
Service
|
|
Type: |
Underground |
Meter Location: |
Side of garage |
Voltage: |
240 |
|
|
|
|
Panel
|
|
Location: |
Garage |
Manufacturer: |
Siemens |
|
- Electrical final on 5/5/2007 |
Type: |
Dual bus bar |
Panel Rating: |
200 AMP |
Main Disconnect: |
200 AMP |
Serv. wire Size/ Rating: |
200 AMP |
Sub-panel: |
No |
Grounding: |
Copper to exterior ground rod, limited visibility |
Panel Clearance: |
30” wide, 3’ in front as required |
|
Exterior grounding |
|
|
|
|
|
Breakers/ Wiring
|
|
Type: |
Copper romex |
Breakers: |
No visible defects |
|
- Arc fault breakers tested |
|
Arc fault breakers were tested
|
|
No evidence of over heating |
|
|
|
Domestic Water
|
|
Supply: |
Public water per listing, not included in this inspection |
Supply Pipe: |
Plastic pipe where visible |
House Piping: |
Plastic where visible |
Pipe Condition: |
Satisfactory where visible |
Main Water Shut off: |
@ pantry |
|
Domestic Water Shut off |
|
Plastic domestic water supply pipe |
|
|
|
|
|
Sanitary Sewer
|
|
Discharge: |
Septic system; not included in this inspection |
|
- Recommend consultation with licensed septic system installer regarding the proper operation and maintenance of this septic system |
House Piping: |
ABS where visible |
Pipe Condition: |
Satisfactory where visible |
|
Septic system controls and alarm |
|
ABS waste lines |
|
Emergency furnace- blower system |
|
|
Emergency Furnace and blower system
|
|
Location: |
Garage |
Make/ Model: |
Rheem Criterion manufactured 09/2006 |
Fuel Type: |
Propane |
BTUH Input: |
75,000 |
BTUH Output: |
- Not noted on furnace |
Efficiency Rating: |
Mid-efficiency |
|
|
|
|
Heat Pump
|
|
Location: |
Exterior |
Make/Model: |
Rheem s/n 7351 M2806 16735 |
|
Exterior heat pump |
|
Heat pump data plate |
|
|
|
|
|
Useful Life
|
|
Est. Useful Life new: |
25 years |
Est. age of furnace: |
6 years +- |
|
- Recommend servicing of furnace by a licensed furnace technician and every (2) years thereafter. There is no visible tag that this furnace has ever been serviced |
|
|
|
|
Heat Exchanger |
|
Visible Inspection: |
No visible defects, limited visibility |
Gas detection test: |
No gas leak detected |
Burner test: |
No burner irregularities detected |
|
|
|
|
Operation |
|
Thermostat: |
Programmable @ floor 1 hall |
Combustion Air: |
Appears adequate |
Filter: |
Located above emergency furnace |
|
Furnace filter location |
|
|
|
|
|
Flue/ Gas Piping |
|
Flue Secure: |
Inspected |
Flue clearances: |
Per requirements where visible |
|
|
|
|
Heat Gain
|
|
Rating: |
25-55 deg F |
@ return air: |
69 deg F +- |
@ nearest register: |
109 deg F +- |
Heat Gain: |
40 deg F. Heat gain is within specifications of furnace |
|
Temperature measured at return air |
|
Temperature measured at heat register |
|
|
Temperature in cooling mode |
|
|
|
|
Water Heater
|
|
Location: |
Garage |
Make/ Model: |
American Water Heater s/n 0642106292 |
Fuel Type: |
Propane |
Capacity: |
75 gallon |
|
|
|
|
Useful Life
|
|
Est. Useful Life new: |
12 years |
Est. age of heater: |
6 years +- |
|
|
|
|
Safety
|
|
TMP valve: |
As per required |
Earthquake Straps: |
Installed |
Expansion Tank: |
Installed |
Flame Rollout: |
No visible evidence |
Safe water temperature: |
120 deg F per industry standards, temperature not measured |
|
|
|
|
Flue
|
|
Secure: |
Inspected |
Clearances: |
As required where visible |
Draft Hood: |
Inspected |
|
|
Site
|
|
Grade at structure: |
Adequate grade away |
Earth to wood contact: |
- Structure in contact with ground (WDO conducive condition). Recommend 4-6” separation between ground and structure |
Vegetation contact: |
Negligible |
Roof drain discharge: |
Underground discharge |
|
Ground in contact with structure @ entry |
|
Ground in contact with structure @ garage-entry |
|
|
|
|
|
Driveway
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Front walks/ steps
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Rear walks/ steps
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Miscellaneous
|
|
Overhead Power Lines: |
N/A |
Retaining Walls: |
None that affect structure |
Underground Oil Tank: |
No visible evidence |
|
|
General Condition
|
|
Structural Movement: |
No visible evidence |
Exterior doors: |
Satisfactory |
Windows (ext. cladding): |
Satisfactory |
|
|
|
|
Siding
|
|
Type: |
Hardboard |
Condition: |
Satisfactory |
Window/Door Flashing: |
Satisfactory |
Caulking: |
Satisfactory |
|
- South wall of house should be re-caulked and maintained. This wall is in direct exposure to the Sun |
|
Failed caulking at South facing siding |
|
|
|
|
|
Roof
|
|
Estimated Pitch: |
7:12 |
Material: |
Composition |
Layers: |
1+ |
How Inspected: |
From eave at (4) locations, floor 2, and from street and rear yard |
Condition: |
Satisfactory |
Ventilation: |
Eave and roof vents |
Plumbing Vents: |
Satisfactory |
Flues: |
Satisfactory |
Flashing: |
Satisfactory |
|
- Roofing or flashing should be installed at all fascia tails |
|
Exposed fascia tail |
|
|
Reverse slope at gutter above the Living Room
|
|
Debris at Dining Room gutter |
|
|
Minor wear and debris on Living room roof |
|
Wear at garage roof (left of entry) |
|
|
|
|
|
Electrical
|
|
Outlets: |
Tested, GFCI protected |
Switches/Lights: |
Tested |
|
|
|
|
Plumbing
|
|
Hose Bibs: |
- Covered, not tested |
Gas Piping: |
Inspected |
|
|
General
|
|
Visibility: |
Space is vacant |
Access location: |
Pantry |
How viewed: |
Traversed entire crawlspace
|
|
Crawlspace (typical) |
|
|
|
|
|
Moisture
|
|
Ventilation: |
Appears adequate |
Vapor Barrier: |
As required |
Moisture Intrusion: |
No visible evidence |
Sump Pump: |
None visible |
|
Drainage outfall beneath the Living Room |
|
|
|
|
|
Structural
|
|
Foundation: |
No visible defects |
Mudsill: |
No visible defects |
Joists: |
No visible defects; limited visibility |
Post-Beams: |
Satisfactory |
Structural Movement: |
No visible evidence |
|
|
|
|
Insulation
|
|
Under-floor: |
Satisfactory |
Domestic Water Pipes: |
Satisfactory |
Heating Supply: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Condition: |
Satisfactory |
Valves/ Other: |
- Pressure reducing valve located near crawlspace access |
|
Pressure reducing valve |
|
|
|
|
|
Electrical
|
|
Outlets: |
None visible |
Wiring/ junction boxes: |
No visible defects |
|
|
|
|
Heating/ Ventilation
|
|
Duct Work: |
- Air and heat loss at trunk line (approximately 10 feet from the crawl access) |
Gas Piping: |
No visible defects |
|
Gap at trunk line |
|
|
|
|
|
Structural Pests
|
|
Conducive Material: |
No visible evidence |
Visible Evidence: |
No visible evidence |
|
|
|
|
Nuisance Pests
|
|
Visible Evidence: |
No visible evidence |
Type: Attached |
|
|
General Room Condition
|
|
Visibility: |
Space is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Slab: |
Satisfactory |
|
|
|
|
Safety
|
|
Fire separation: |
As required where visible |
Ignition point > above FF: |
In compliance |
Safety barricade to mech.: |
In compliance |
|
|
|
|
Garage Door
|
|
Type: |
Metal roll-up |
|
|
Springs & Fasteners: |
No visible defects |
Auto Reverse: |
Tested |
Photocell reverse: |
Tested |
Remote openers: |
Not present |
|
Damaged weather stripping |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
Tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Doors
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
|
|
General Room Condition
|
|
Visibility: |
Rooms are occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
North wall framing |
|
N.W. wall framing (Dining room) |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floor 1 |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
|
|
|
|
Appliances
|
|
Dishwasher: |
Tested full cycle |
Dishwasher air gap: |
Visible |
Oven: |
Tested |
Cooktop: |
Tested |
Microwave: |
Not tested |
Ventilation: |
Tested |
Refrigerator: |
Tested |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Disposal: |
- Garbage disposals are typically not recommended with a septic system. Recommend consultation with licensed septic system installer |
Caulking: |
Satisfactory |
Fixtures: |
No visible defects |
|
- Faucet spray handle counterweight needs adjustment (to hold spray handle tight to faucet) |
|
Adjust counter weight on hose |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
|
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
- Evidence of prior ceiling repairs. No active plumbing leaks detected above |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Screen: |
|
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
|
- Door latch at rear exterior door needs adjustment or replacement |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
|
Fireplace
|
|
Type: |
Sealed gas direct vent |
Tested: |
Ignition tested |
|
Power outage backup ignition batteries |
|
Location: Floor 1 |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
|
Mirrors: |
Satisfactory |
|
Grout missing at floor tiles |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
- Adjacent spaces |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floor 1 |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested. Bathroom outlets are GFCI protected |
Smoke detector: |
Yes |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floors 1 and 2 |
|
|
General Room Condition |
|
Visibility: |
Space is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
Yes |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
|
Stairwell |
|
Handrails: |
As required |
Barricades: |
As required |
Balusters: |
As required |
Trip Hazard: |
None |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
A portion of the wall behind the bed appears to have a header |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested. Bathroom outlets are GFCI protected |
|
- Tub jet motor is GFCI protected |
Smoke detector: |
Yes |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
- Towel bar is loose |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
|
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Rooms are occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
|
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is occupied |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
- Outlet for countertop is not installed |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Fixtures: |
No visible defects |
|
|
|
|
Appliances
|
|
Washer: |
Tested rinse cycle |
Dryer Connection: |
Electric |
Dryer: |
Tested. Vented to outside |
Appliance Condition: |
Satisfactory |
Location: Over main body of house |
|
|
General
|
|
Visibility: |
Space is vacant |
Access location: |
Master Bedroom closet |
|
- Attic access above the garage was obstructed by personal belongings, not accessed |
How viewed: |
Traversed entire attic space |
|
Attic space (typical) |
|
Attic space (typical) |
|
|
|
|
|
Moisture
|
|
Roof Ventilation: |
- Evidence of microbial growth above the Master Bathroom and North wall above the Master Bedroom. Recommend install timer style bathroom fan switch and additional roof ventilation above the North roof area |
Moisture Intrusion: |
No visible evidence |
Bath/Kitchen fans : |
All vent to outside |
|
Evidence of microbial growth above the Master Bathroom (skylight area) |
|
Evidence of microbial growth at the North facing roof |
|
|
|
|
|
Structural
|
|
Structure Type: |
Manufactured trusses |
Sheathing: |
OSB |
Structural Movement: |
No visible evidence |
|
|
|
|
Insulation
|
|
Type: |
Blown in |
Approximate Depth: |
10” +- |
Condition: |
Satisfactory |
|
|
|
|
Flues/Vent Stacks
|
|
Plumbing Stacks: |
All vented to exterior |
Gas Flues: |
No visible defects |
|
|
|
|
Electrical
|
|
Outlets: |
None visible |
Wiring/ junction boxes: |
No visible defects |
|
|
|
|
Structural Pests
|
|
Conducive Material: |
No visible evidence |
Visible Evidence: |
No visible evidence |
|
|
|
|
Nuisance Pests
|
|
Visible Evidence: |
No visible evidence |
Wood Destroying Organisms (WDO) |
|
Conducive Conditions (CC) |
||
WDO-AB |
Anobid Beetles |
|
CC-BG |
Bare Ground |
WDO-CA |
Carpenter Ants |
|
CC-CD |
Conducive Debris |
WDO-DT |
Dampwood Termites |
|
CC-EM |
Excessive Moisture |
WDO-MA |
Moisture Ants |
|
CC-EW |
Earth-Wood Contact |
WDO-OB |
Other Beetles |
|
CC-FC |
Failed Caulking |
WDO-RF |
Rot Fungus |
|
CC-IV |
Inadequate Ventilation |
WDO-ST |
Subterranean Termites |
|
CC-RG |
Restricted Gutter |
|
|
|
CC-VC |
Vegetation Contact |
Inspection Conditions (IC) |
|
|
|
|
IC-CSA |
Crawl Space Access |
|
|
|
IC-IA |
Inadequate Clearance |
|
|
|
|