Home Inspection Sammamish


Client:

 

Address:

 

 

Property Description:

 

(2) story single family home with attached garage

Occupancy Status:

Staged

 

Inspection Date:

 

01/07/2012

Inspection Time:

12:30 P.M. – 3:00 P.M. +-

Weather Conditions:

Overcast, 50 deg F +-

 

 

Table of Contents

 


 

Summary of Inspection....................................................................................................... 3

Electrical System................................................................................................................. 5

Plumbing System................................................................................................................. 7

Heating System................................................................................................................... 8

Water Heater..................................................................................................................... 11

Site..................................................................................................................................... 13

Building Exterior............................................................................................................... 14

Crawlspace........................................................................................................................ 17

Garage............................................................................................................................... 19

Living Room, Dining Room, and Den.............................................................................. 20

Floor 1 Bathroom.............................................................................................................. 21

Family Room..................................................................................................................... 22

Kitchen and Nook............................................................................................................. 23

Hallways............................................................................................................................ 25

Master Bedroom Suite....................................................................................................... 27

Utility Room...................................................................................................................... 28

Bedrooms 2, 3, and 4........................................................................................................ 29

Main Bathroom.................................................................................................................. 30

Bonus Room...................................................................................................................... 31

Attic................................................................................................................................... 32

Structural Pest Inspection Diagram................................................................................... 33

 

Summary of Inspection

 

All items listed in the Summary of each section are listed below. Additional comments may be written in the body of the report. Please read the entire report. All items listed below should be further evaluated, inspected, modified, and/or corrected by a licensed professional in that corresponding or related trade.

 

WDO refers to “Wood Destroying Organism” as defined by the Washington State Department of Agriculture

 

- Items in this font are general comments throughout report.

- Items in this font are considered a minor cost and/or cosmetic.

- Items in this font are considered a substantial cost or an extreme safety concern.

 

 

Electrical System

Plumbing System

Heating System

- Condensation is dripping from the pipe into the emergency drip catch pan

- Inadequate working space in front of furnace. This area should be 3’ in depth. Furthermore, the metal beneath the furnace is unsupported at the outer side and is conducive to a service technician falling thru the ceiling

- Explain the operation of the mechanical air intake and heating system. What activates the system ? How is the temperature set ?

Water Heater

- Pipes above the water heater made loud noises at random during the inspection. Recommend further evaluation by a licensed plumbing contractor

- Adjust hot water temperature to 120 deg F

Site

- North side yard slopes towards the house. Is there a specific drainage system below grade ? Why doesn’t this area slope towards a V ditch at the property line ?

- Is the 4” pipe on the South side yard a drainage or side sewer clean out ? The pipe should be cut and capped to grade

Building Exterior

- Touch up exterior trim at entryway

- Wood plant shelf at the Kitchen should be sloped to prevent wood rot

- Exposed OSB sheathing at fireplace should be sealed (add trim)

- Cut building paper from below siding at rear steps

- Add roofing or flashing at upper surface of all fascia (barge) tails

- Downspout at South side of entry should be properly secured

- Gutters should be cleaned of debris

- Exterior rear light inoperative (burnt out light bulb ?)

- Paint gas pipes with rust proof paint

- Gas earthquake valve is significantly out of level

Crawlspace

- Provide documentation that the ends of most of the floor trusses were designed and built without a vertical connection between the top and bottom cords (no field modifications; cut off ends)

- The floor trusses are supported by the mudsill which is exposed to the weather in several areas (non-louvered crawlspace vents). What provision has been made to prevent wind driven rain from entering the vents, collecting on the mudsill, and then rotting the untreated floor trusses ?

Garage

Living Room, Dining Room, and Den

- Stationary door strike at Den is not in the correct location

Floor 1 Bathroom

- Paint on floor tile near doorway

- Erratic water spray pattern from the shower head

Family Room

- Touch up paint above mantle

- Add batteries to back up battery compartment in the fireplace

Kitchen and Nook

- Hardwood floors to be repaired of scratches per agreement with buyer

- Properly secure false drawer front at cooktop (remove random part pinned between)

- Repair hole in cabinet above vent hood (add new skin overlay ?)

- Grout tile backsplash to window casing. Re-caulk countertop to backsplash

- Clean disposal of debris

- Sink faucet fully rotates. Set rotation limiters if available

- Electrical outlet not provided at right side of sink. Provide code provision that would allow this omission

Hallways

- Touch up walls and ½ wall near bedroom area of floor 2

- Touch up lower side of window sill at upper window of foyer

- Paint on carpeting near bonus room door

- Upper window at foyer is dirty. Clean window and verify no scratches on window

- Adjust weather-stripping at base of door from garage to house. Adjust strike plate for proper seal at upper left corner of the door (viewed from the interior)

Master Bedroom Suite

- Hot water valve for the shower does not function properly

Utility Room

Bedrooms 2, 3, and 4

Main Bathroom

- Erratic flow pattern from the bathtub spout

Bonus Room

- Stationary door strike is not in the correct location

- Active door will not stay in the fully open position

Attic

 

 

Electrical System

 

 

 

Home Inspection Sammamish

 

 

                                                                       

 

Service

 

Type:

Underground

Meter Location:

Side of garage

Voltage:

240

 

 

 

 

Panel

 

 

Location:

Garage

Manufacturer:

Square D

Type:

Dual bus bar

Panel Rating:

200 AMP

Main Disconnect:

200 AMP

Serv. wire Size/ Rating:

200 AMP

Sub-panel:

No

Grounding:

Copper to EUFER ground,  limited visibility

Panel Clearance:

30” wide, 3’ in front as required


 

 

Home Inspection Sammamish

EUFER grounding

 

 

 

 

 

 

Breakers/ Wiring

 

 

Type:

Copper romex

Breakers:

No visible defects

 

- Arc fault breakers tested

 

 

 

Home Inspection Sammamish

No evidence of over heating

 

 

Plumbing System

 

 

                                   

Domestic Water

 

Supply:

Public water per listing, not included in this inspection

Supply Pipe:

Poly pipe where visible 

House Piping:

Pex type where visible

Pipe Condition:

Satisfactory where visible

Main Water Shut off:

@ garage


 

 

Home Inspection Sammamish

Domestic Water Shut off

 

Home Inspection Sammamish

Hose bib shut off

 

 

 

 

 

 

Sanitary Sewer

 

 

Discharge:

Public sewer per listing, not included in this inspection

House Piping:

ABS where visible

Pipe Condition:

Satisfactory where visible


 

 

Home Inspection Sammamish

ABS waste lines

 

Heating System

 

 


Home Inspection Sammamish

 


 

Furnace

 

Location:

Attic

Make/ Model:

York s/n WIG1170687

Fuel Type:

Natural gas

BTUH Input:

80,000

BTUH Output:

76,000

Efficiency Rating:

High-efficiency

 

 

 

 

Useful Life

 

 

Est. Useful Life new:

25 years

Est. age of furnace:

1 year +-

 

 

 

 

Heat Exchanger

 

Visible Inspection:

No visible defects, limited visibility

Gas detection test:

No gas leak detected

Burner test:

No burner irregularities detected

 

 

 

 

Operation

 

Thermostat:

Programmable @ floor 1

Disconnect:

Switch on truss near furnace

Combustion Air:

Appears adequate

Filter:

Located at floor 2 return air

 

- Condensation is dripping from the pipe into the emergency drip catch pan

 

- Inadequate working space in front of furnace. This area should be 3’ in depth. Furthermore, the metal beneath the furnace is unsupported at the outer side and is conducive to a service technician falling thru the ceiling


 

 

Home Inspection Sammamish

Furnace filter location

 

 

Home Inspection Sammamish

Unsupported metal beneath the furnace

Inadequate work space in front of furnace

 

 

 

Home Inspection Sammamish

Condensation dripping into emergency drip pan

 

 

 

 

 

 

Flue/ Gas Piping

 

Flue Secure:

Inspected

Flue clearances:

Per requirements where visible

Gas Piping:

Drip leg installed

 

 

 

 

Heat Gain

 

 

Rating:

35-65 deg F

 @ return air:

79 deg F

@ nearest register:

120 deg F

           Heat Gain:

41 deg F. Heat gain is within specifications of furnace

 


 

 

Home Inspection Sammamish

Temperature measured at return air

 

 

Home Inspection Sammamish

Temperature measured at heat register

 

 



 

 

Home Inspection Sammamish

Electric heating system in garage

 

 

Home Inspection Sammamish

Heated air is brought into the interior when the cooktop ventilation system is active

 

Water Heater

 


Home Inspection Sammamish

 

                                   


 

Water Heater

 

Location:

Garage

Make/ Model:

Rheem  manufactured 09/2011

Fuel Type:

Natural gas

Capacity:

50 gallon

 

 

 

 

Useful Life

 

 

Est. Useful Life new:

12 years

Est. age of heater:

1 year +-

 

- Pipes above the water heater made loud noises at random during the inspection. Recommend further evaluation by a licensed plumbing contractor

 

 

 

 

Safety

 

 

TMP valve:

As per required

Earthquake Straps:

Installed

Expansion Tank:

Installed

Flame Rollout:

No visible evidence


 

 

Home Inspection Sammamish

Recirculation system

 

 

Home Inspection Sammamish

Expansion tank is functioning as designed

 (hot water has not filled the expansion tank)

 

 

 

 

 

 

Flue

 

 

Secure:

Inspected

Clearances:

As required where visible

Draft Hood:

Inspected

 

 

 

 

Water Temperature

 

 

Safe water temperature:

120 deg F per industry standards

Measured temperature:

125 deg F

 

- Adjust hot water temperature to 120 deg F

 


 

Home Inspection Redmond

 

 


Site

                                 



 

 

Home Inspection Redmond

Pipe at South side yard

 

Home Inspection Redmond

Side yard slopes towards the house

 

 

 

 

 

 

Driveway

 

 

    Type:

Concrete

  Condition:

Satisfactory

  Trip Hazard:

None

 

 

 

 

Front walks/ steps

 

 

    Type:

Concrete

  Condition:

Satisfactory

  Trip Hazard:

None

 

 

 

 

Rear walks/ steps

 

 

    Type:

Concrete

  Condition:

Satisfactory

  Trip Hazard:

None

 

 

 

 

Miscellaneous

 

 

Overhead Power Lines:

N/A

Retaining Walls:

None that affect structure

Underground Oil Tank:

No visible evidence

Irrigation System:

None visible

Building Exterior

                                 


 

General Condition

 

Structural Movement:

No visible evidence

Exterior doors:

Satisfactory

Windows (ext. cladding):

Satisfactory

 

 

 

 

Siding

 

 

    Type:

Hardboard

  Condition:

Satisfactory

 

- Touch up exterior trim at entryway

 

- Wood plant shelf at the Kitchen should be sloped to prevent wood rot

 

- Exposed OSB sheathing at fireplace should be sealed (add trim)

 

- Cut building paper from below siding at rear steps

Window/Door Flashing:

Satisfactory

  Caulking:

Satisfactory


 

 

Home Inspection Redmond

Horizontal wood surface is prone to rot

 

 

Home Inspection Redmond

Touch up at entryway

 

 

Home Inspection Redmond

Exposed OSB at fireplace

 

Home Inspection Redmond

Building paper below siding near rear patio

 

 

 

 

 

 

Roof

 

 

Estimated Pitch:

6:12

Material:

Composition

Layers:

1+

How Inspected:

From eave at (1) locations and from street and rear yard

Condition:

Satisfactory

 

- Add roofing or flashing at upper surface of all fascia (barge) tails

Ventilation:

Eave and roof vent

Plumbing Vents:

Satisfactory

Flues:

Satisfactory

Flashing:

Satisfactory


 

 

Home Inspection Redmond

Missing roofing or flashing

 


 

 

 

 

Gutters/ Downspouts

 

 

Type:

Continuous metal

Condition:

Satisfactory

 

- Downspout at South side of entry should be properly secured

 

- Gutters should be cleaned of debris


 

 

Home Inspection Redmond

Unsecured downspout

 

Home Inspection Redmond

Debris in gutters

 

 

 

 

 

 

Electrical

 

 

Outlets:

Tested, GFCI protected

Switches/Lights:

Tested

 

- Exterior rear light inoperative (burnt out light bulb ?)

 

 

 

 

Plumbing

 

 

Hose Bibs:

Anti-siphon

Gas Piping:

Inspected

 

- Paint gas pipes with rust proof paint

 

- Gas earthquake valve is significantly out of level


 

 

Home Inspection Redmond

Rust at gas piping

 

 

Home Inspection Redmond

Gas valve is out of level

 

Crawlspace

                               


 

General

 

Visibility:

Space is vacant

Access location:

Entry coat closet

How viewed:

Traversed entire crawlspace

 

 

 

 

Moisture

 

 

Ventilation:

Appears adequate

Vapor Barrier:

As required

Moisture Intrusion:

No visible evidence

Sump Pump:

None visible

 

 

 

 

Structural

 

 

Foundation:

No visible defects

Mudsill:

No visible defects

Joists:

- Provide documentation that the ends of most of the floor trusses were designed and built without a vertical connection between the top and bottom cords (no field modifications; cut off ends)

Post-Beams:

Satisfactory

Structural Movement:

No visible evidence


 

 

Home Inspection Redmond

No vertical connection at outer edges

 of most floor trusses

 

 

 

 

 

 

Insulation

 

 

Under-floor:

Satisfactory

Domestic Water Pipes:

Satisfactory

 

 

 

 

Plumbing

 

 

Condition:

Satisfactory

Valves/ Other:

None visible

 

 

 

 

Electrical

 

 

Outlets:

None visible

Wiring/ junction boxes:

No visible defects

 

 

 

 

 

Structural Pests

 

 

Conducive Material:

No visible evidence

 

- The floor trusses are supported by the mudsill which is exposed to the weather in several areas (non-louvered crawlspace vents). What provision has been made to prevent wind driven rain from entering the vents, collecting on the mudsill, and then rotting the untreated floor trusses ?

Visible Evidence:

No visible evidence

 

 

 

 

Nuisance Pests

 

 

Visible Evidence:

No visible evidence

Garage

 

Type: Attached

                                   


 

General Room Condition

 

Visibility:

Space is vacant

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Slab:

Satisfactory

 

 

 

 

Safety

 

 

Fire separation:

As required where visible

Ignition point > above FF:

In compliance

Safety barricade to mech.:

- Not needed

 

 

 

 

Garage Door

 

 

Type:

Metal roll-up

Springs & Fasteners:

No visible defects

Auto Reverse:

n/a

Photocell reverse:

n/a

Remote openers:

n/a

 

 

 

 

Electrical

 

 

Switches/Lights:

Tested

Outlets:

All visible tested, GFCI protected

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Fixed

 

 

 

 

Doors

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Living Room, Dining Room, and Den

                                  


 

General Room Condition

 

Visibility:

Rooms are staged

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested

 

 

 

 

Heating

 

 

Source:

Ceiling register

Air Flow/ Heat Gain:

Satisfactory

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

 

- Stationary door strike at Den is not in the correct location

Door condition:

Satisfactory

Millwork condition:

Satisfactory

Floor 1 Bathroom

 

Location: Floor 1

                                   


 

General Room Condition

 

Visibility:

Room is vacant

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

 

- Paint on floor tile near doorway

Cabinets:

Satisfactory

Countertops:

Satisfactory

Mirrors:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested, GFCI protected

 

 

 

 

Heating

 

 

Source:

Ceiling register

Air Flow/ Heat Gain:

Satisfactory

Mechanical ventilation:

Tested

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

As required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

Bath Hardware:

Satisfactory

 

 

 

 

Plumbing

 

 

Functional flow:

Appears adequate

Hot/ Cold:

Tested

Drainage:

Appears adequate

Visible leaks:

None visible

Caulking:

Satisfactory

Toilet Secure:

Satisfactory

Tub/Shower surround:

Satisfactory

                Fixtures:

- Erratic water spray pattern from the shower head

Family Room

                                   


 

General Room Condition

 

Visibility:

Room is staged

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

 

- Touch up paint above mantle

Ceiling:

Satisfactory

Flooring:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested

 

 

 

 

Heating

 

 

Source:

Ceiling register

Air Flow/ Heat Gain:

Satisfactory

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

 

 

 

 

Fireplace

 

 

Type:

Sealed gas direct vent

Tested:

Ignition tested

 

- Add batteries to back up battery compartment in the fireplace

Kitchen and Nook

 

Location: Floor 1

                           


 

General Room Condition

 

Visibility:

Rooms are staged

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

- Hardwood floors to be repaired of scratches per agreement with buyer

Cabinets:

Satisfactory

 

- Properly secure false drawer front at cooktop (remove random part pinned between)

 

- Repair hole in cabinet above vent hood (add new skin overlay ?)

Countertops:

Satisfactory

 

- Grout tile backsplash to window casing. Re-caulk countertop to backsplash

 

 


 

 

Home Inspection Redmond

Gap between tile backsplash and window casing

 

 

Home Inspection Redmond

Random part pinned in between false drawer and cabinet box

 


 

 

 

 

Appliances

 

 

Dishwasher:

Tested full cycle

Dishwasher air gap:

Visible

Oven:

Tested

Cooktop:

Tested

Microwave:

Not tested

Ventilation:

Tested

Refrigerator:

n/a

 

 

 

 

Plumbing

 

 

Functional flow:

Appears adequate

Hot/ Cold:

Tested

Drainage:

Appears adequate

Visible leaks:

None visible

Disposal:

- Clean disposal of debris

Caulking:

Satisfactory

Fixtures:

- Sink faucet fully rotates. Set rotation limiters if available

 

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested, GFCI protected

 

- Electrical outlet not provided at right side of sink. Provide code provision that would allow this omission


 

 

Home Inspection Redmond

No electrical outlet to right of sink

 


 

 

 

 

Heating

 

 

Source:

Ceiling register

Air Flow/ Heat Gain:

Satisfactory

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

Hallways

 

Location: Floors 1 and 2

                                 


 

General Room Condition

Visibility:

Space is vacant

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

 

- Touch up walls and ½ wall near bedroom area of floor 2

 

- Touch up lower side of window sill at upper window of foyer

Ceiling:

Satisfactory

Flooring:

Satisfactory

 

- Paint on carpeting near bonus room door

 

 


 

 

Home Inspection Redmond

Paint on carpeting near Bonus Room

 

 

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested

Smoke Detector:

Tested

 

 

 

 

Windows

 

 

Glazing:

No visible defects

 

- Upper window at foyer is dirty. Clean window and verify no scratches on window

Tempered:

Not required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

 

- Adjust weather-stripping at base of door from garage to house. Adjust strike plate for proper seal at upper left corner of the door (viewed from the interior)

Millwork condition:

Satisfactory


 

 

Home Inspection Redmond

Air infiltration at base of door from garage to house

 

 

 

 

 

 

Stairwell

 

Handrails:

As required

Barricades:

As required

Balusters:

As required

Trip Hazard:

None

Master Bedroom Suite

 

Location: Floor 2

                                  


 

General Room Condition

 

Visibility:

Room is staged

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

Cabinets:

Satisfactory

Countertops:

Satisfactory

Mirrors:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested. Bathroom outlets are GFCI protected

Smoke detector:

Yes

 

 

 

 

Heating

 

 

Source:

Floor register

Air Flow/ Heat Gain:

Satisfactory

Mechanical ventilation:

Tested

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

As required

Operation:

Tested

Egress:

Appears to meet current egress standards

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

Bath Hardware:

Satisfactory

 

 

 

 

Plumbing

 

 

Functional flow:

Appears adequate

Hot/ Cold:

- Hot water valve for the shower does not function properly

Drainage:

Appears adequate

Visible leaks:

None visible

Caulking:

Satisfactory

Toilet Secure:

Satisfactory

Tub/Shower surround:

Satisfactory

               Fixtures:

No visible defects

Utility Room

 

Location: Floor 2

                                


 

General Room Condition

 

Visibility:

Room is vacant

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

Cabinets:

Satisfactory

Countertops:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested, GFCI protected

 

 

 

 

Heating

 

 

Source:

Floor register

Air Flow/ Heat Gain:

Satisfactory

Mechanical ventilation:

Tested

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

 

 

 

 

Plumbing

 

 

Functional flow:

Appears adequate

Hot/ Cold:

Tested

Drainage:

Appears adequate

Visible leaks:

None visible

Caulking:

Satisfactory

                Fixtures:

No visible defects

 

 

 

 

Appliances

 

 

Washer:

- Recommend install drip fan beneath clothes washer with drainage to the exterior

Dryer Connection:

Electric

Dryer:

n/a Vented to outside

Appliance Condition:

n/a

Bedrooms 2, 3, and 4

 

Location: Floor 2

                                  


 

General Room Condition

 

Visibility:

Rooms are staged

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested

Smoke Detector:

Tested

 

 

 

 

Heating

 

 

Source:

Floor register

Air Flow/ Heat Gain:

Satisfactory


 

 

Home Inspection Redmond

Heating wall stacks in the North Bedroom will likely make this room warmer than others

 


 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Tested

Egress:

Appears to meet current egress standards

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

Main Bathroom

 

Location: Floor 2


                                  


 

General Room Condition

 

Visibility:

Room is staged

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

Cabinets:

Satisfactory

Countertops:

Satisfactory

Mirrors:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested, GFCI protected

 

- This GFCI outlet is the reset location for all of the bathrooms

 

 

 

 

Heating

 

 

Source:

Floor register

Air Flow/ Heat Gain:

Satisfactory

Mechanical ventilation:

Tested

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

As required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

Tested

Door condition:

Satisfactory

Millwork condition:

Satisfactory

Bath Hardware:

Satisfactory

 

 

 

 

Plumbing

 

 

Functional flow:

Appears adequate

Hot/ Cold:

Tested

Drainage:

Appears adequate

Visible leaks:

None visible

Caulking:

Satisfactory

Toilet Secure:

Satisfactory

Tub/Shower surround:

Satisfactory

                Fixtures:

- Erratic flow pattern from the bathtub spout

Bonus Room

                                   


 

General Room Condition

 

Visibility:

Room is vacant

Structural Movement:

No visible evidence

Moisture Infiltration:

No visible evidence

Walls:

Satisfactory

Ceiling:

Satisfactory

Flooring:

Satisfactory

 

 

 

 

Electrical

 

 

Switches/Lights:

All visible tested

Outlets:

All visible tested

Smoke Detector:

- None

 

 

 

 

Heating

 

 

Source:

Floor register

Air Flow/ Heat Gain:

Satisfactory

 

 

 

 

Windows

 

 

Glazing:

No visible defects

Tempered:

Not required

Operation:

Tested

Screen:

No visible defects

 

 

 

 

Doors/Millwork

 

 

Operation/latching:

- Stationary door strike is not in the correct location

 

- Active door will not stay in the fully open position

Door condition:

Satisfactory

Millwork condition:

Satisfactory


 

 

Home Inspection Redmond

Door strike is in the wrong location

 

Attic

 

Location: Over main body of house

                                  


 

General

 

Visibility:

Space is vacant

Access location:

Bedroom access

How viewed:

From furnace platform

 

 

 

 

Moisture

 

 

Roof Ventilation:

Appears adequate

Moisture Intrusion:

No visible evidence

Bath/Kitchen fans :

All vent to outside

 

 

 

 

Structural

 

 

Structure Type:

Manufactured trusses

Sheathing:

OSB

Structural Movement:

No visible evidence

 

 

 

 

Insulation

 

 

Type:

Blown in

Approximate Depth:

10” +-

Condition:

Satisfactory

 

 

 

 

Flues/Vent Stacks

 

 

Plumbing Stacks:

All vented to exterior

Gas Flues:

No visible defects

 

 

 

 

Electrical

 

 

Outlets:

None visible

Wiring/ junction boxes:

No visible defects

 

 

 

 

Structural Pests

 

 

Conducive Material:

No visible evidence

Visible Evidence:

No visible evidence

 

 

 

 

Nuisance Pests

 

 

Visible Evidence:

No visible evidence

Structural Pest Inspection Diagram

 

 

Wood Destroying Organisms (WDO)

 

Conducive Conditions

(CC)

WDO-AB

Anobid Beetles

 

CC-BG

Bare Ground

WDO-CA

Carpenter Ants

 

CC-CD

Conducive Debris

WDO-DT

Dampwood Termites

 

CC-EM

Excessive Moisture

WDO-MA

Moisture Ants

 

CC-EW

Earth-Wood Contact

WDO-OB

Other  Beetles

 

CC-FC

Failed Caulking

WDO-RF

Rot Fungus

 

CC-IV

Inadequate Ventilation

WDO-ST

Subterranean Termites

 

CC-RG

Restricted Gutter

 

 

 

CC-VC

Vegetation Contact

Inspection Conditions

(IC)

 

 

 

IC-CSA

Crawl Space Access

 

 

 

IC-IA

Inadequate Clearance

 

 

 

 